FILIGRAN® offers various types of lattice girders, which are sized to order. When the order is placed, the lattice girder height (H), lower chord diameter (LC), upper chord size (UC) and diameter of diagonals (D) are specified.

Possible dimensions are stated below or can be found in the Product range.

Here are some weights of typical lattice girders.

While putting up lattice girder by means of textile slings the following rules have to be obeyed.

Example: The girder designation E15-06712 means: type E, height H =15, LC=06, D=7, UC=12

Type E Application Cert. App.
H: 6 - 40 cm
LC: 5 - 14 mm
D: 5 - 9 mm
UC: 5 - 16 mm
Semi-precast slab
Semi-precast wall
Beam and block floor
downloaddownload
downloaddownload
downloaddownload
download
download
download
DatasheetDatenblatt
Type D Application Cert. App.
H: 6 - 20 cm
LC: 5 - 14 mm
D: 5 - 7 mm
UC: 5 - 16 mm
Semi-precast slab
Semi-precast wall
Beam and block floor
Lintels
download
download
download
download
download
download
DatasheetDatenblatt
Type FIL Anwendung Cert. App.
H: 7 - 18 cm
LC: 6 - 14 mm
D: 7 mm
UC: 16 mm
Semi-precast slab
Beam and block floor
downloaddownload
downloaddownload

download
download

DatasheetDatenblatt
Type EV Application Cert. App.
H: 18 - 40 cm
LC: 6 - 14 mm
D: 9 (7/8) mm
UC: 16 (10) mm

Semi-precast slab

downloaddownload

download

DatasheetDatenblatt
Type EQ Application Cert. App.
H: 8 - 30 cm
LC: 5 (6) mm
D: 7 mm
UC: 5 (6) mm
Semi-precast slab
Semi-precast wall
downloaddownload
downloaddownload
download
download
high shear forces, dynamic load
DatasheetDatenblatt
Type S Application Cert. App.
H: 11 - 42 cm
LC: 6 - 16 mm
D: 7 - 9 (10) mm
UC: 40 x 2 mm
Beam and block floor
Semi-precast wall
download
download
download
download
DatasheetDatenblatt
Type DH Application Cert. App.
H: 6 - 20 cm
LC: 5 - 14 mm
D: 5 - 7 mm
UC: 5 - 16 mm
Beam and block floor
Lintels
download download
DatasheetDatenblatt
Type EH Application Cert. App.
H: 7 - 40 cm
LC: 5 - 14 mm
D: 5 - 9 mm
UC: 5 - 16 mm
Beam and block floor
Lintels
downloaddownload download
DatasheetDatenblatt
Type SWE Application Cert. App. Gittertraeger-Typ-SWE
H: 12 - 41 cm
LC: 5 - 12 mm
D: 5 - 9 mm
UC: 5 - 12 mm
Semi-precast wall download download
DatasheetDatenblatt
Type SWA Application Cert. App. gittertraeger-typ-sw
H: 12 - 41 cm
LC: 5 - 12 mm
D: 5 - 9 mm
UC: 5 - 12 mm
Semi-precast wall download download
DatasheetDatenblatt
Type SE2 Application Cert. App. gittertraeger-typ-s
H: 12 - 41 cm
LC: 5 - 12 mm
D: 5 - 9 mm
UC: 5 - 12 mm
Semi-precast wall
Beam and block floor
Lintels
download
download
download
download
core-insulated walls with stainless steel diagonals
DatasheetDatenblatt
Type SE Application Cert. App.
H: 12 - 41 cm
LC: 5 - 16 mm
D: 5 - 9 mm
UC: 5 - 12 mm
Semi-precast wall
Beam and block floor
Lintels
download
download
 
download
download
DatasheetDatenblatt
Type DSP Application Cert. App. gittertraeger-typ-d
H: 6 - 20 cm
LC: 5 - 14 mm
D: 5 - 7 mm
UC: 5 - 16 mm
Slatted floor   download
DatasheetDatenblatt
Type DSH Application Cert. App.
H: 6 - 20 cm
LC: 5 - 14 mm
D: 5 - 7 mm
UC: 5 - 16 mm
Slatted floor
 
download
DatasheetDatenblatt

European Certificates